LT Electrical and Automation Panels

Sysnix engineers low-tension power and automation panels around the actual load list, fault level, control philosophy, site environment and maintenance requirements. Power distribution, motor control, PLC hardware, drives, protection and communication are coordinated as one documented panel system.

LT Control Panels capabilities

Typical applications

Business and engineering outcomes

Safer maintainability

Clear segregation, device labeling, terminal planning and drawings help plant teams isolate and service circuits.

Application-matched protection

Loads, starting duty, fault inputs, environment and coordination requirements guide component selection.

Cleaner automation integration

PLC, drive, metering and communication hardware are planned with power and EMC considerations from the start.

Documented expansion

Spare capacity and as-built records make later additions more predictable.

Engineering and delivery approach

  1. Electrical inputs: Verify load list, motor data, incoming supply, fault-level inputs, cable details, environment and project standards.
  2. Detailed engineering: Prepare SLD, GA, power and control drawings, bill of material, terminal plans and panel heat considerations.
  3. Assembly and inspection: Check enclosure, busbar, wiring, earthing, labels, devices, clearances and drawing conformity.
  4. Functional testing: Test control power, protections, I/O, interlocks, communications and agreed FAT sequences before dispatch.
  5. Site integration: Support installation checks, cable termination verification, energization and commissioning.

Platforms, protocols and components

Panel types

Integrated equipment

Documentation

What we need to start

Project deliverables

Frequently asked questions

Which LT panels can you engineer?

Typical projects include PCC, MCC, APFC, AMF, VFD, soft-starter, PLC and remote-I/O panels. The final design depends on the approved load and project specification.

Do you provide panel drawings?

Yes. The agreed documentation can include SLD, GA, power and control schematics, terminal plans, cable schedules and bill of material.

Can an old control panel be replaced without changing the machine?

Often yes. We first survey the existing I/O, loads, interlocks, field wiring, space and shutdown constraints before planning the retrofit.

Are protection and busbar ratings project-specific?

Yes. Ratings must be selected from verified load, fault-level, installation, ambient and applicable project-standard inputs rather than a generic panel template.